IMPs and Sustainable Construction: What They Really Bring to the Table

Written by Norbec | Nov 18, 2026, 1:13:04 AM

 

Insulated metal panels (IMPs) are gaining popularity in non-residential construction as an integrated building envelope solution. Designing with IMPs gives building owners, architects and contractors a competitive edge in today’s design-build market. Drawing on advanced technology, these prefabricated panels outperform conventional building systems in efficiency and longevity, while contributing to LEED (Leadership in Energy and Environmental Design) certification. Combining aesthetics and flexibility, IMPs expand design possibilities, helping designers bring their most creative architectural visions to life.

What Is an IMP?

An IMP, also known as a sandwich panel, consists of a rigid insulating core between two steel facings. Norbec offers two types of cores:

  • NOREX®: a polyisocyanurate (PIR) foam core, selected for its high thermal resistance;
  • NOROC®: a non-combustible stone wool core made from natural basalt rock fibres and recycled slag, for projects where fire resistance is a priority.

Panels can be installed vertically or horizontally—even diagonally—and used as exterior building envelope systems, interior partitions or ceilings.

Energy Efficiency: Where IMPs Make a Real Difference

A building’s carbon footprint includes operational carbon, associated notably with the energy used for heating and cooling, as well as embodied carbon, associated with the manufacture, transportation, installation, maintenance and end-of-life treatment of its construction materials1. For IMPs, reducing embodied carbon involves improving the environmental profile of their main constituents: steel and insulating foam2. During building operation, their insulating properties and contribution to envelope airtightness can reduce heating and cooling demand and, depending on the energy sources used, the associated greenhouse gas (GHG) emissions.

  • Thermal Resistance: According to the NOREX® environmental technical data sheet, its declared thermal resistance is R-7.41 per inch of thickness. This thermal resistance helps limit heat transfer through the building envelope. The performance of the complete wall assembly also depends on joints, fasteners and connections to other building elements.
  • Airtightness: IMPs combine insulation and air barrier functions in a single panel. Proper sealing of panel joints and connections at openings, roofs and foundations is essential to maintain air barrier continuity and limit energy losses caused by air leakage. Overall performance therefore also depends on detailing and installation quality. While the building code requires air leakage rates of 0.20 L/(s·m²) or less, the panels can achieve rates as low as 0.02 L/(s·m²), depending on the configuration.
  • Measured Long-Term Performance: Like all closed-cell foam insulation, PIR foam loses some of its thermal resistance over time. To measure this effect, the foam used in NOREX® underwent long-term thermal resistance (LTTR) testing. Using accelerated laboratory aging, this test predicts thermal resistance after five years. At a thickness of 50 mm (2 in.), the foam achieved an LTTR of 2.4 m²·K/W (R-13.6 h·ft²·°F/Btu), compared with the minimum of 1.80 m²·K/W (R-10.1 h·ft²·°F/Btu) required by CAN/ULC-S704. It is important to note that the test method used, CAN/ULC-S770, is designed for unfaced rigid insulation and underestimates IMP performance because it excludes the impermeable facings that slow the diffusion of insulating gases. Better long-term performance can therefore be expected.

Actual energy savings depend on the climate, building use and design. Energy modelling remains the best approach for a project-specific estimate.

Built for Longevity

Sustainable construction also means keeping materials in service. For an IMP building envelope, long-term preservation depends notably on exposure conditions, the selected finish, installation quality and maintenance. Panel selection should therefore reflect the service environment and project requirements.

The goal is to preserve the building envelope’s functions and limit premature replacement, which requires new materials and creates additional impacts. Manufacturer warranties and performance testing can help inform this choice, but a warranty alone is not a measure of a product’s service life. It is therefore important to select materials and finishes suited to your project. Norbec’s technical teams can help you select the right products.

  • Warranties: Norbec architectural panels carry a five-year warranty against manufacturing defects, including delamination, subject to the applicable terms and conditions. The surface finish is covered separately. Depending on the selected coating system, the finish warranty may exceed 30 years.

Transparency: Third-Party-Verified Data

Norbec publishes environmental and health-related product information so design teams can assess the products for themselves.

  • Environmental Product Declaration (EPD): Compliant with ISO 14025 and independently verified, the EPD for NOROC® and NOREX® panels reports the products’ environmental impacts from raw material extraction to the factory gate.
  • Health Product Declarations (HPDs): The HPDs for NOREX® and NOROC® (available in English) disclose the panels’ chemical ingredients and associated hazards using the HPD Collaborative’s standardized format.
  • Environmental Technical Data Sheets: Validated by Vertima, these documents provide information including recycled content, material sourcing and VOC emissions. See the 2025 NOROC® data sheet and the NOREX® data sheet.

Contributing to LEED® Certification

A product cannot make a building LEED® certified on its own, but it can contribute to meeting specific credit requirements. Norbec IMPs can contribute to the following LEED® v4 credits and prerequisite:

  • Materials and Resources – Building Product Disclosure and Optimization – Environmental Product Declarations: through a product-specific Type III EPD compliant with ISO 14025;

  • Materials and Resources – Building Product Disclosure and Optimization – Sourcing of Raw Materials: through documented pre-consumer and post-consumer recycled content, accounted for in accordance with the credit’s calculation rules;

  • Materials and Resources – Building Product Disclosure and Optimization – Material Ingredients: through Health Product Declarations (HPDs) documenting product composition in accordance with the applicable requirements;

  • Energy and Atmosphere – Minimum Energy Performance (Prerequisite): through their contribution to the building envelope’s thermal performance, assessed in the building energy model.

  • Energy and Atmosphere – Optimize Energy Performance: through their contribution to reducing heating and cooling demand, assessed in the building energy model against the baseline building. 

Since April 2025, Canadian projects have also been able to register under LEED® v5, which places a strong emphasis on decarbonization and embodied carbon. Verified EPD data are particularly useful in this context, as they directly support whole-building life cycle assessment.

 

For more information, visit Norbec’s LEED® page.

Blowing Agents and Health

The PIR foam used in NOREX® is manufactured without chlorofluorocarbons (CFCs) or hydrochlorofluorocarbons (HCFCs), using blowing agents with zero ozone depletion potential and a global warming potential of less than 13.

Learn More

All documents mentioned in this article are available in the Documentation section of Norbec’s website. Contact our team for more information.

 

This article was prepared with support from artificial intelligence for structuring and rewording the text. The data, sources and technical statements were verified by Norbec’s team, which takes responsibility for the published content.

 

Sources

  1. Ordre des architectes du Québec. (n.d.). Glossaire [Glossary]. Guide Mieux concevoir. https://www.oaq.com/ressources/guide-mieux-concevoir/glossaire/
  2. Metal Construction Association. (2012). Life cycle assessment report. https://www.metalconstruction.org/index.php/online-education/life-cycle-assessment-report
  3. Haltermann Carless. (2025, August). Pentanes: The smart choice for energy-efficient innovation [Brochure], p. 10. https://www.haltermann-carless.com/hubfs/Dokumente/Website/brochure_HC_Pentanes_eng.pdf